Page 95 Power Equipment Usage Manual (Rev. 5/10)
19.2. Setup & Use – Plunge Router
CAUTION: Before connecting router to power source, ALWAYS MAKE SURE
SWITCH IS IN THE “OFF” POSITION.
19.2.1. Selecting the Bit
Routers are furnished with 1/4" and 1/2" diameter collets that will accommodate bits with 1/4" or 1/2"
diameter shanks that are installed directly into the power unit collet.
19.2.2. Installing & Removing the Bit
CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
a. Remove motor unit from base unit as follows:
Loosen clamp screw (A) Figure 1.
While holding base, turn motor unit
COUNTERCLOCKWISE until lower pin (B) in
motor housing is disengaged from groove in
base.
Lift motor unit free from base unit.
b. Clean and insert shank of bit into collet until shank bottoms. Then back it out approximately
3/8” to 1/2“.
c. Lay motor unit on its side on bench with the collet
pointing AWAY from you.
d. Place one wrench on flats on chuck with the opposite
end of the wrench resting on the bench to your left,
Figure 2.
e. Place other wrench on collet and tighten
COUNTERCLOCKWISE as shown in Figure 2. TIGHTEN
FIRMLY.
AVOID POSSIBLE DAMAGE TO COLLET. NEVER TIGHTEN COLLET WITHOUT BIT.
f. To remove the bit, reverse the foregoing procedure.